Our Products

 

A sound masking system consists of a series of speakers installed in a grid-like pattern. A central control panel and software provide fine control over zoning and settings.

 

 
  • Control Panel
  • Keypad
  • Software
  • Primary Hub
  • Secondary
    Hub
  • Loudspeaker
  • Cables
  • Accessories
 

Software

Acoustic Network Manager can be used to control the LogiSon Acoustic Network when linked to a Network Control Panel via Ethernet or wireless connection.


This software gives the user the same control over the system that the Network Control Panel provides, but through an attractive visual interface. The interface is configurable to show or hide functionality based on the user or installation type. Communication is protected by 128-bit AES encryption.


Commands can be sent to one, a group or all Primary Hubs. The user can establish timer, paging and keypad zones. There are no restrictions on the size of each type of zone and they can be non-contiguous. The user can also set the volume and equalizer levels for masking and paging, program ramp-up and timer schedules, select paging channels, and create user limits for each Programmable Keypad. Hub indicators show hub types, hardware status, volume and muting.


Settings can be saved to an electronic file or printed for record-keeping purposes. The application includes a help file and user guide.

Technical Specifications

Control Performance

Functions Communication setup, Network setup, masking, paging, timer, keypad settings, audio inputs and diagnostics

Masking Performance

Volume 35 to 85 dBA, 0.5 dBA steps, mute
Equalization 1/3-octave, 23 bands
Preset Contours 50 options

Paging Performance

Zone Configuration Zone 1, 2, 3 or mute (per Primary Hub)
Volume 35 to 85 dBA, 0.5 dBA steps, mute
Equalization 1/1-octave, 8 bands
Preset Contours 50 options

Timer Performance

Number of Zones 1 to 9
Size of Zones Unrestricted
Timer Schedules Unique schedules for each weekday
Volume Changes Per Day 9
Rate of Change 0 to 9 minutes per increment
Volume Increments 0.5 dBA steps
Introductory Ramp Up 1 to 15 day user-defined schedule; option of 0.5 or 1 dBA steps
Exception Schedules 3 user-defined schedules; up to 30 exception dates
Delayed-On Feature Yes
Daylight Savings Adjustment Automatic; option of preset international or user-defined schedule