Hubs


Primary hubs are connected to the control panel in series, which enables you to program the zoning and settings for the loudspeakers. This setup also offers multiplexed audio without the need for additional sound generators, amplifiers or equalizers.

Content coming soon.

Secondary Network Hub, SNH-1

Secondary Network Hub, SNH-1

Up to two Secondary Network Hubs can be connected to each primary hub, offering zones that are 1 to 3 loudspeakers in size (225 to 675 ft2). Each zone offers 100 volume steps in 0.5 dBA increments and 1/3-octave frequency control..

This small zone size and fine control over settings allows the LogiSon® Acoustic Network’s masking sound to be tuned to accommodate local needs, ensuring that it’s both effective and unobtrusive across the entire space.

Secondary Network Hubs are typically mounted to the deck or another approved structure within the ceiling. A loudspeaker is suspended from each one. Each Secondary Network Hub replicates the settings of the primary hub to which it is connected.

The Secondary Network Hub is available in white or charcoal grey.

 

Product Sheet 

  Print this information by downloading our product sheet

Specifications

Output Performance

Masking, paging and timer inherited from Primary Hub

Components per Hub

1 loudspeaker

Connections

 

Signal Input / Output

2-pin x 2

Loudspeaker Output

2-pin

Cabling

 

PNH to SNH

CA2 series cable

SNH to SNH

CA2 series cable

Power

0 W

Physical Specifications

Dimensions (W x H)        

13.0 x 4.5 cm; 5.1 x 1.75 inches

Enclosure

Plenum-rated resin

Color

White or charcoal grey

Weight

0.2 kg; 0.4 lb

Mounting

Flexible mounting options; see LogiSon® Installation Manual

Security

No physical controls

Warranty

5 years; see LogiSon® Product Warranty for details

Certifications

Meets UL, CA, ACMA (C-Tick) and FCC standards and is approved for use in air-handling plenums; RoHS compliant